# Retrieve ACK



Use the following endpoint to retrieve the E2B acknowledgement message (ACK) after sending an intake call:

<Endpoint path="/api/{version}/app/safety/intake/ack" method="GET"></Endpoint>
The Retrieve ACK endpoint can be used with the following Safety intake endpoints:

* Intake Inbox Item

* Intake Imported Case

## Headers {#headers}

<FieldTable>
| Name | Description |
| --- | --- |
| `Accept` | `application/json` |
</FieldTable>

## URL Parameters {#url-parameters}

<FieldTable>
| Name | Description |
| --- | --- |
| `inbound_id` | The Inbound Transmission ID for the ICSR intake job. |
</FieldTable>

## Request {#request}

<CodeExample title="">
```
curl --location --request GET 'https://myvault.veevavault.com/api/v20.2/app/safety/intake/ack?inbound_id=V29000000005001' \
--header 'Authorization: {SESSION_ID}' \
--header 'Content-Type: multipart/form-data' \
--form 'file=@"/directory/e2b_r3_restolar.xml"' \
--form 'format="e2br3__v"'

```
</CodeExample>

## Response {#response}

<CodeExample title="">
```
<?xml version="1.0" encoding="utf-8"?>
<MCCI_IN200101UV01 xmlns="urn:hl7-org:v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="urn:hl7-org:v3 http://eudravigilance.ema.europa.eu/xsd/multicacheschemas/MCCI_IN200101UV01.xsd" ITSVersion="XML_1.0">
    <!--ACK.M.1 - Acknowledgement Batch Number-->
    <id root="2.16.840.1.113883.3.989.2.1.3.20" extension="b4e413b2-7263-48b5-b957-839fea7c7edc"/>
    <!--ACK.M.4 - Date of Message-->
    <creationTime value="20210618154357-0400"/>
    <!--Mandatory element-->
    <responseModeCode code="D"/>
    <interactionId extension="MCCI_IN200101UV01" root="2.16.840.1.113883.1.6"/>
    <MCCI_IN000002UV01>
        <!--ACK.B.r.2 - Local Report Number-->
        <id root="2.16.840.1.113883.3.989.2.1.3.19" extension="VERN-123-123-123"/>
        <!--ACK.M.4 - ACK Date of Batch Transmission-->
        <creationTime value="20210618154357-0400"/>
        <interactionId root="2.16.840.1.113883.1.18" extension="MCCI_IN000002UV01"/>
        <processingCode code="P"/>
        <processingModeCode code="T"/>
        <acceptAckCode code="NE"/>
        <receiver typeCode="RCV">
            <device determinerCode="INSTANCE" classCode="DEV">
                <!--ACK.B.r.3: ICSR Message Receiver Identifier-->
                <id root="2.16.840.1.113883.3.989.2.1.3.16" extension="ICHTEST"/>
            </device>
        </receiver>
        <sender typeCode="SND">
            <device determinerCode="INSTANCE" classCode="DEV">
                <!--ACK.B.r.4: ICSR Message Sender Identifier-->
                <id root="2.16.840.1.113883.3.989.2.1.3.15" extension="DSJP"/>
            </device>
        </sender>
        <attentionLine>
            <!--ACK.B.r.5 - Receipt date-->
            <keyWordText codeSystemVersion="2.0" codeSystem="2.16.840.1.113883.3.989.2.1.1.24" code="1"/>
            <value value="20120720100001+09" xsi:type="TS"/>
        </attentionLine>
        <!--ACK.B.r.6 - Acknowledgement Report Code-->
        <acknowledgement typeCode="CA">
            <targetMessage>
                <!--ACK.B.r.1 - Safety Report ID ICSR Message Number-->
                <id root="2.16.840.1.113883.3.989.2.1.3.1" extension="VERN-123-123-123"/>
            </targetMessage>
            <acknowledgementDetail>
                <!--ACK.B.r.7 - Error/Warning message / comment-->
                <text>[F.r.5 Normal High Value (Unit), mg/dl] inconsistent_unit; [C.5.3, 0105798/01] unable_to_link_study_for_wrong_type; [C.5.1.r.1, 2004-09102-03] unable_to_link_study_for_wrong_type; [C.5.1.r.2, EU] unable_to_link_study_for_wrong_type; [C.5.1.r.1, NL...</text>
            </acknowledgementDetail>
        </acknowledgement>
    </MCCI_IN000002UV01>
    <receiver typeCode="RCV">
        <device determinerCode="INSTANCE" classCode="DEV">
            <!--ACK.M.3 - Acknowledgement Batch Receiver Identifier-->
            <id root="2.16.840.1.113883.3.989.2.1.3.18" extension="DSJP"/>
        </device>
    </receiver>
    <sender typeCode="SND">
        <device determinerCode="INSTANCE" classCode="DEV">
            <!--ACK.M.2 - Acknowledgement Batch Sender Identifier-->
            <id root="2.16.840.1.113883.3.989.2.1.3.17" extension="ICHTEST"/>
        </device>
    </sender>
    <attentionLine>
        <!--ACK.A.2 - Local Message Number-->
        <keyWordText codeSystemVersion="2.0" codeSystem="2.16.840.1.113883.3.989.2.1.1.24" code="2"/>
        <value root="2.16.840.1.113883.3.989.2.1.3.21" extension="TR-000006_b4e413b2-7263-48b5-b957-839fea7c7edc_20210618194357" xsi:type="II"/>
    </attentionLine>
    <attentionLine>
        <!--ACK.A.3 - Date of ICSR Batch Transmission-->
        <keyWordText codeSystemVersion="2.0" codeSystem="2.16.840.1.113883.3.989.2.1.1.24" code="3"/>
        <value value="20120720100000" xsi:type="TS"/>
    </attentionLine>
    <!--ACK.A.4- Transmission Acknowledgment Code-->
    <acknowledgement typeCode="AE">
        <targetBatch>
            <!--ACK.A.1 - ICSR Batch Number -->
            <id root="2.16.840.1.113883.3.989.2.1.3.22" extension="DSJP-B0123456"/>
        </targetBatch>
        <!--ACK.A.5 - Batch Validation Error-->
        <acknowledgementDetail>
            <text>[F.r.5 Normal High Value (Unit), mg/dl] inconsistent_unit; [C.5.3, 0105798/01] unable_to… See B.r.7</text>
        </acknowledgementDetail>
    </acknowledgement>
</MCCI_IN200101UV01>

```
</CodeExample>

## Response Details {#response-details}

On SUCCESS, the response returns the ACK XML. The ACK is returned in the same E2B format as the intake file.

On FAILURE, the response returns a message describing the reason for the failure.



---

**Previous:** [Retrieve Intake Status](/safety/vault-api/api-reference/23.2/safety/intake/retrieve-intake-status)  